Organization:YUNG TA PUMPS ENTERPRISE CO., LTD.
Name of Lab:Pump performance testing laboratory
Add. of Lab:No.6, Ln.94, Sec.1, Balian Rd., Sijhih Dist., New Taipei City 221, Taiwan
Accreditation Number:3244
Accreditation Criteria:ISO/IEC 17025:2017 ;CNS 17025:2018
Water Pumps
M 204 Head Loss
CNS 660 Sec. 3.A.1.a, 3.B.2.a, 3.C
Pressure Gauge Range:(0 to 20) kgf/cm^2
Vacuum Gauge Range:(-1 to 0) kgf/cm^2
Water-level Measuring Apparatus:(0 to 1.5) m
ISO 9906 AnnexD.1.3 Electronic Pressure Transducers
CNS 16017 AnnexD.1.3 Electronic Pressure Transducers
(-0.1 to 2.5) MPa, (-1 to 25) bar
M 205 Discharge Capacity
Triangle Weir:(0.1098 to 1.9843) m^3/min
Rectangular Weir:(0.4684 to 18.4053) m^3/minCNS 661 Sec. 5, 6
ISO 9906 AnnexD.3.7 Electromagnetic Method
CNS 16017 AnnexD.3.7 Electromagnetic Method
(0.235 to 16.67) m3/min
M 206 Power and Efficiency
CNS 663
ISO 9906 Sec. 3.2.26, 3.2.27, 3.2.30
CNS 16017 Sec. 3.2.26, 3.2.27, 3.2.30